AM58K CANopen®
6.9 Warning objects
For the complete list and meaning of the warning messages please refer to “SDO
abort codes” section in “CiA Draft Standard 301” document available at
6.10 Emergency objects
Emergency (EMCY) objects are issued by the device when an internal error
occurs.
EMCY structure:
IDENTIFIER
CAN Data Byte
COB-ID(hex)
0
1
2
3…7
see object
Error code
Error Sub-
register
Specific code
LSB
MSB
01
00…00
Available error codes:
1000h =
Node guarding error
5530h =
Flash memory error
MAN AM58K CB E 1.1.odt
47
6 - CANopen® interface