Section 2. Initial assembly
In the eddy covariance system enclosure (7900-050), install the Power Distribution
Kit (7900-235) on the raised DIN rail. Connect the red wire lead between the top of
the breaker and top right red terminal. Install one shorting block to connect all
black terminals and another to connect all red terminals.
Figure 2-1. The power distribution kit (7900-235) installed in the enclosure (7900-050).
2-2