Section 2. Initial assembly
Connecting power wires
Note:
Do not power on the RV50X yet. Leave the breakers OFF until later in the
process (see
Cut the power cable to a suitable length (30 to 50 cm) and carefully remove about
5 cm (2") of outer insulation. Strip about 1.3 cm (½") of insulation from the black,
red, and white wires. Twist the red and white wires together. The green wire is not
used. Connect the wire leads to suitable power terminals in the enclosure.
From
Wire Color
To
DIN Terminal 11 (top) or Black DIN Terminal
black
RV50X Ground (-)
DIN Terminal 13 (top) or Red DIN Terminal
red and white
RV50X Power (+)
Table 2-1
. RV50X power wire connections for the Biomet Data Acquisition System
enclosure or the eddy covariance system enclosure.
2-6