Section 6.
Troubleshooting
Power on problems
Check the power supply wire connections to be sure all the connections are secure.
Depending upon what is included in the system, the devices typically require
between 12 and 28 VDC at 3 Amps (the maximum voltage allowed depends on
components in the system). Check the power supply voltage at the enclosure to be
sure it is adequate. With long power cables, expect some voltage drop between the
origin and end of the cable. Be sure adequate voltage is delivered to each com-
ponent in the system.
For the RV50X, be sure that both the white and red power supply wires are con-
nected to the (+) power supply. The white lead controls a switch in the RV50X that
must be activated before the RV50X will power on.
Cannot connect to RV50X using ACEmanager
l
Wait a few minutes for the RV50X to initialize; it may just need to finish.
l
Only connect one computer to the RV50X at a time. If you have connected mul-
tiple computers to the RV50X simultaneously, restart the RV50X and try con-
necting again.
l
Restart your web browser or use a different web browser.
l
Restart your computer.
l
Check the Ethernet cable to be sure it is good. Swap it out with another one to
test it.
l
Check the user name and password.
6-1
AirLink Cellular Communication
Summary of Contents for AirLink RV50X
Page 2: ......
Page 6: ...iv ...
Page 10: ...viii ...
Page 14: ...Section 1 Introduction to the communication system 1 4 AirLink Cellular Communication ...
Page 28: ...Section 2 Initial assembly 2 10 AirLink Cellular Communication ...
Page 36: ...Section 3 Configuring instrument IP addresses 3 8 AirLink Cellular Communication ...
Page 52: ...Section 4 Configuring the RV50X 4 16 AirLink Cellular Communication ...
Page 66: ...Section 6 Troubleshooting 6 4 AirLink Cellular Communication ...
Page 68: ...Section 7 Maintenance 7 2 AirLink Cellular Communication ...
Page 89: ......