3. Distributor type MULTI F DX (3 phase)
7
_
Heat pump 50Hz/R410A
Part 2 Product data_Outdoor units
Models : A8UW48LFA0 [FM49AH U32]
[Cooling capacity]
19
11,400
3.3
18,535
5.4
20,900
6.1
840
1,222
1,665
20
12,000
3.5
19,510
5.7
22,000
6.4
880
1,282
1,746
21
12,600
3.7
20,486
6.0
23,100
6.8
920
1,341
1,827
22
13,200
3.9
21,461
6.3
24,200
7.1
960
1,401
1,908
23
13,800
4.0
22,437
6.6
25,300
7.4
1,000
1,460
1,989
24
14,400
4.2
23,412
6.9
25,705
7.5
1,085
1,520
2,071
25
15,000
4.4
24,388
7.1
26,776
7.8
1,128
1,579
2,152
26
15,600
4.6
25,363
7.4
27,847
8.2
1,170
1,639
2,233
27
16,200
4.7
26,339
7.7
28,918
8.5
1,213
1,698
2,314
28
16,800
4.9
27,314
8.0
29,989
8.8
1,256
1,758
2,395
29
17,400
5.1
28,290
8.3
31,060
9.1
1,298
1,817
2,476
30
18,000
5.3
29,265
8.6
32,131
9.4
1,355
1,897
2,584
31
18,600
5.5
30,241
8.9
33,202
9.7
1,412
1,976
2,693
32
19,200
5.6
31,216
9.1
34,273
10.0
1,468
2,056
2,801
33
19,800
5.8
32,192
9.4
35,344
10.4
1,525
2,135
2,909
34
20,400
6.0
33,167
9.7
36,415
10.7
1,582
2,215
3,018
35
21,000
6.2
34,143
10.0
37,486
11.0
1,639
2,294
3,126
36
21,600
6.3
35,118
10.3
38,557
11.3
1,696
2,374
3,235
37
22,200
6.5
36,094
10.6
39,628
11.6
1,752
2,453
3,343
38
22,800
6.7
37,069
10.9
40,699
11.9
1,809
2,533
3,451
39
23,400
6.9
38,045
11.2
41,770
12.2
1,866
2,613
3,560
40
24,000
7.0
39,020
11.4
42,841
12.6
1,923
2,692
3,668
41
24,600
7.2
39,996
11.7
43,912
12.9
1,980
2,772
3,776
42
25,200
7.4
40,971
12.0
44,983
13.2
2,037
2,851
3,885
43
25,800
7.6
41,947
12.3
46,054
13.5
2,093
2,931
3,993
44
26,400
7.7
42,922
12.6
47,125
13.8
2,122
2,971
4,047
45
27,000
7.9
43,898
12.9
48,196
14.1
2,150
3,010
4,102
46
27,600
8.1
44,873
13.2
49,268
14.4
2,179
3,050
4,156
47
28,200
8.3
45,849
13.4
50,339
14.8
2,207
3,090
4,210
48
28,800
8.4
46,824
13.7
51,410
15.1
2,236
3,130
4,265
49
29,400
8.6
47,800
14.0
52,481
15.4
2,264
3,170
4,319
50
30,000
8.8
48,164
14.1
52,881
15.5
2,299
3,219
4,373
51
30,600
9.0
48,529
14.2
53,281
15.6
2,335
3,269
4,428
52
31,200
9.1
48,893
14.3
53,680
15.7
2,370
3,318
4,482
53
31,800
9.3
49,257
14.4
54,080
15.9
2,405
3,367
4,537
54
32,400
9.5
49,621
14.5
54,480
16.0
2,440
3,416
4,591
55
33,000
9.7
49,986
14.6
54,880
16.1
2,476
3,466
4,645
56
33,600
9.8
50,350
14.8
55,280
16.2
2,511
3,515
4,700
57
34,200
10.0
50,714
14.9
55,680
16.3
2,546
3,564
4,754
58
34,800
10.2
51,079
15.0
56,080
16.4
2,581
3,614
4,808
59
35,400
10.4
51,443
15.1
56,480
16.6
2,616
3,663
4,863
60
36,000
10.6
51,807
15.2
56,880
16.7
2,652
3,712
4,917
61
36,600
10.7
52,171
15.3
57,280
16.8
2,687
3,761
4,971
62
37,200
10.9
52,536
15.4
57,680
16.9
2,722
3,811
5,026
63
37,800
11.1
52,900
15.5
58,080
17.0
2,757
3,860
5,080
Total indoor unit
capacity
(kBtu/h)
Min
Cooling capacity
Rated
Max
Btu/h
kW
Btu/h
kW
Btu/h
kW
Min
Rated
Max
Input (W)
Note :
1. Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB
; outdoor temp. 35°C DB, 24°C WB
2. Heating Capacity is based on : indoor temp.20°C DB, 15°C WB
; outdoor temp. 7°C DB, 6°C WB
3. The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant.
Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.
4. Total capacity index of indoor unit should be within 19~63 Btu/h(40%~130%)
5. At least two indoor units should be connected.