Heat Pump 50Hz/R410A
_
49
1. Multiple piping type MULTI F
Part 2 Product data_Outdoor units
7+9
7+12
9+9
9+12
22
4.46
0.68
4.74
0.92
5.02
1.00
5.16
1.01
5.58
1.02
5.85
1.02
25
4.35
0.73
4.63
0.95
4.91
1.03
5.05
1.04
5.47
1.06
5.75
1.07
32
4.11
0.98
4.39
1.15
4.67
1.21
4.81
1.22
5.22
1.25
5.50
1.27
35
4.00
1.09
4.28
1.24
4.56
1.28
4.69
1.26
5.12
1.32
5.40
1.35
40
3.83
1.20
4.11
1.29
4.39
1.31
4.53
1.31
4.94
1.33
5.22
1.36
43
3.72
1.17
4.00
1.23
4.28
1.22
4.42
1.22
4.84
1.23
5.12
1.26
46
3.62
1.05
3.90
1.06
4.18
1.04
4.31
1.03
4.73
1.03
5.01
1.05
22
4.46
0.68
4.74
0.92
5.02
1.00
5.16
1.01
5.58
1.02
5.85
1.02
25
4.35
0.73
4.63
0.95
4.91
1.03
5.05
1.04
5.47
1.06
5.75
1.07
32
4.11
0.98
4.39
1.15
4.67
1.21
4.81
1.22
5.22
1.25
5.50
1.27
35
4.00
1.09
4.28
1.24
4.56
1.28
4.69
1.26
5.12
1.32
5.40
1.35
40
3.83
1.20
4.11
1.29
4.39
1.31
4.53
1.31
4.94
1.33
5.22
1.36
43
3.72
1.17
4.00
1.23
4.28
1.22
4.42
1.22
4.84
1.23
5.12
1.26
46
3.62
1.05
3.90
1.06
4.18
1.04
4.31
1.03
4.73
1.03
5.01
1.05
22
4.46
0.68
4.74
0.92
5.02
1.00
5.16
1.01
5.58
1.02
5.85
1.02
25
4.35
0.73
4.63
0.95
4.91
1.03
5.05
1.04
5.47
1.06
5.75
1.07
32
4.11
0.98
4.39
1.15
4.67
1.21
4.81
1.22
5.22
1.25
5.50
1.27
35
4.00
1.09
4.28
1.24
4.56
1.28
4.69
1.26
5.12
1.32
5.40
1.35
40
3.83
1.20
4.11
1.29
4.39
1.31
4.53
1.31
4.94
1.33
5.22
1.36
43
3.72
1.17
4.00
1.23
4.28
1.22
4.42
1.22
4.84
1.23
5.12
1.26
46
3.62
1.05
3.90
1.06
4.18
1.04
4.31
1.03
4.73
1.03
5.01
1.05
22
4.46
0.68
4.74
0.92
5.02
1.00
5.16
1.01
5.58
1.02
5.85
1.02
25
4.35
0.73
4.63
0.95
4.91
1.03
5.05
1.04
5.47
1.06
5.75
1.07
32
4.11
0.98
4.39
1.15
4.67
1.21
4.81
1.22
5.22
1.25
5.50
1.27
35
4.00
1.09
4.28
1.24
4.56
1.28
4.69
1.26
5.12
1.32
5.40
1.35
40
3.83
1.20
4.11
1.29
4.39
1.31
4.53
1.31
4.94
1.33
5.22
1.36
43
3.72
1.17
4.00
1.23
4.28
1.22
4.42
1.22
4.84
1.23
5.12
1.26
46
3.62
1.05
3.90
1.06
4.18
1.04
4.31
1.03
4.73
1.03
5.01
1.05
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
Combination
capacity index
(kBtu/h)
Outdoor
air temp.:
(°CDB)
Operation
14 16
18 19 22 24
Indoor air temp.: (°CWB)
2 Units
Notes:
1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5m
Level difference : 0m
2. TC : Total Capacity (kW)
PI : Power Input (kW)