Heat pump
50Hz/R410A
_
4
3. Distributor type MULTI F DX (3 phase)
Part 2 Product data_Outdoor units
Note :
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 5m(Main)+5m(Branch).
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
Outdoor unit
A9UW56LFA0
[FM57AH U32]
Testing Combination
MS09AQ NB0 x 7EA
Capacity
Cooling
Min.
∼
Rated
∼
Max.
kW
4.0 ~ 15.5 ~ 18.5
Min.
∼
Rated
∼
Max.
Btu/h
13,800 ~ 52,900 ~ 63,200
Heating
Min.
∼
Rated
∼
Max.
kW
4.5 ~ 17.4 ~ 18.8
Min.
∼
Rated
∼
Max.
Btu/h
15,456 ~ 59,400 ~ 64,000
Power Input
Cooling
Min.
∼
Rated
∼
Max.
kW
1.00 ~ 3.86 ~ 5.86
Heating
Min.
∼
Rated
∼
Max.
kW
1.49 ~ 4.16 ~ 6.19
SEER / SCOP
Wh / Wh
-
Seasonal Energy Label
Cooling / Heating
-
-
Annual Energy Consumption Cooling / Heating
kWh
-
Power Supply
V , Ø , Hz
380-415, 3, 50
Running Current
Cooling
Min.
∼
Rated
∼
Max.
A
2.3 ~ 5.4 ~ 8.4
Heating
Min.
∼
Rated
∼
Max.
A
2.5 ~ 5.5 ~ 9.0
Starting Current
Cooling
Max.
A
-
Heating
Max.
A
-
Wiring Connections
Power Supply Cable (included Earth)
Outdoor Unit
No. x mm
2
(AWG)
5C x 2.5 (12)
Power and transmission cable
No. x mm
2
(AWG)
4C x 1.25 (16)
Combination
Sum of Indoor Units Capacity
kBtu/h
73
Number of Indoor Units
EA
9
Number of BD Units
EA
3
Casing Color
-
Warm Gray
Dimensions
W x H x D
mm
950 × 1,380 × 330
W x H x D
inch
37-13/32 × 54-11/32 × 13
Net Weight
kg (lbs)
96 (211.6)
Compressor
Type
-
Twin Rotary
Model
Model x No.
GPT442MAA x 1
Motor type
-
BLDC
Motor Output
W x No.
4,000 (at 60Hz) x 1
Refrigerant
Type
-
R410A
Precharged Amount
g (oz)
4,400 (155.2)
Chargeless-Pipe
Length
Main Pipe
m (ft)
5 (16.4)
Branch Pipe
m (ft)
45 (147.6)
Additional Charging
Volume
Main Pipe
g/m (oz/ft)
20 (0.22)
Branch Pipe
g/m (oz/ft)
50 (0.54)
Control
-
Electronic Expansion Valve
Refrigerant Oil
Type
-
FVC68D
Charged volume
cc x No.
1,300 x 1
Heat Exchanger
(Row x Column x Fins per inch) x No.
-
(2 x 32 x 14) x2
Fan
Type
-
Propeller
Air Flow Rate
-
60 x 2
Fan Motor
Type
m
3
/min x No.
BLDC
Output
W x No.
124.2 x 2
Sound Pressure
Level
Cooling
Rated
dB(A)
54
Heating
Rated
dB(A)
56
Sound Power Level Cooling
Max.
dB(A)
69
Piping Connections
Liquid
Outer Dia.
mm(inch) x No.
Ø 9.52 (3/8)
Gas
Outer Dia.
mm(inch) x No.
Ø 19.05 (3/4)
Piping Length
Total Piping
Max.
m (ft)
145 (475.7)
Main Piping
Max.
m (ft)
55 (180.4)
Total Branch Piping
Max.
m (ft)
90 (295.3)
Each Branch Piping
Max.
m (ft)
15 (49.2)
Maximum Height
Difference
Outdoor Unit ~ Indoor Unit
Max.
m (ft)
30 (98.4)
Indoor Unit ~ Indoor Unit
Max.
m (ft)
15 (49.2)
Operation Range
(Outdoor Temperature)
Cooling
Min. ~ Max.
℃ DB (℉ DB)
-10 (14.0) ~ 48 (118.4)
Heating
Min. ~ Max.
℃ WB (℉ WB)
-18 (-0.4) ~ 18 (64.4)