Heat pump 50Hz/R410A
_
35
2. Distributor type MULTI F DX (1 phase)
Part 2 Product data_Outdoor units
2) Rate of change in capacity due to the branch piping length
5 / 7k Btu/h 2.1 kW models
9k Btu/h 2.6 kW models
Piping
length(m)
5 100.0 100.0
10 98.0 99.5
15 96.0 98.9
Rate of change in capacity
Cooling(%)
Heating(%)
Piping
length(m)
5 100.0 100.0
10 97.5 98.8
15 95.0 97.5
Rate of change in capacity
Cooling(%)
Heating(%)
12k Btu/h 3.5 kW models
18k Btu/h 5.3 kW models
Piping
length(m)
5 100.0 100.0
10 97.0 98.3
15 94.0 96.5
Rate of change in capacity
Cooling(%)
Heating(%)
24k Btu/h 7.0 kW models
Piping
length(m)
5 100.0 100.0
10 97.8 99.2
15 95.5 98.4
Rate of change in capacity
Cooling(%)
Heating(%)
Piping
length(m)
5 100.0 100.0
10 98.3 99.5
15 96.5 99.0
Rate of change in capacity
Cooling(%)
Heating(%)