8. Electric characteristics
40
Outdoor unit
̰
DHW Tank integrated Unit
Model
Power Supply
for Electric Heater
Indoor Unit
Combination of
Electric Heater
(kW)
Phase
Volts
Hz
Capacity (kW)
Power
Circuit Breaker
(A)
AHNW16606B0
2.0
1~
220-240V
50Hz
2.0
1~ 230V 50Hz
16.0
2.0+2.0
1~
220-240V
50Hz
4.0
1~ 230V 50Hz
20.0
2.0+2.0+2.0
3N~
380-415V
50Hz
6.0
3N~ 400V 50Hz
16.0
[Power Supply for Heat Pump]
[Power Supply for Electric Heater]
Note
1.Voltage supplied to the unit terminals should be within the minimum and maximum range.
2.Maximum allowable voltage unbalance between phase is 2%.
3.Recommended circuit breaker type is ELCB (Earth Leakage Circuit Breaker).