THERMA V
Split Type
2. Specifications
4
Outdoor unit
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Noise Measuring chamber accordance with standard. Therefore, these values depend on the ambient conditions
and values are normally higher in actual operation.
4. Performances are based on the following conditions :
• Cooling : Inlet/Outlet Water Temp. 23°C/18°C, Outdoor Air Temp. 35°CDB / 24°CWB
• Heating : Inlet/Outlet Water Temp. 30°C/35°C, Outdoor Air Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. This product contains Fluorinated greenhouse gases.
6. Sound Performances are based on the following conditions.
• Sound Power Level : Measured according to EN14825.
• Sound Pressure Level : Calculated value according to distance of sound power.
Model Names
Outdoor Unit
AHUW128A3 [HU123 U33]
AHUW148A3 [HU143 U33]
Indoor Unit
AHNW16809A3 [HN1639 NK3]
AHNW16809A3 [HN1639 NK3]
Capacity (Rated)
Cooling
kW
10.4
12.0
Heating
kW
12.0
14.0
Power Input (Rated)
Cooling
kW
2.60
3.08
Heating
kW
2.64
3.18
Current (Rated)
Cooling
A
6.5
7.7
Heating
A
6.6
8.0
Maximum Running Current
Cooling
A
16.1
16.1
Heating
A
16.1
16.1
EER
Cooling
W/W
4.00
3.90
COP
Heating
W/W
4.55
4.41
Prated (Low temp. Average)
kW
9.00
9.50
Prated (High temp. Average)
kW
9.90
9.90
SCOP (Low temp. Average)
W/W
4.45
4.45
SCOP (High temp. Average)
W/W
3.32
3.32
Model Names
Outdoor Unit
AHUW168A3 [HU163 U33]
Indoor Unit
AHNW16809A3 [HN1639 NK3]
Capacity (Rated)
Cooling
kW
13.0
Heating
kW
16.0
Power Input (Rated)
Cooling
kW
3.60
Heating
kW
3.76
Current (Rated)
Cooling
A
9.0
Heating
A
9.4
Maximum Running Current
Cooling
A
16.1
Heating
A
16.1
EER
Cooling
W/W
3.61
COP
Heating
W/W
4.26
Prated (Low temp. Average)
kW
10.00
Prated (High temp. Average)
kW
9.90
SCOP (Low temp. Average)
W/W
4.30
SCOP (High temp. Average)
W/W
3.32
Summary of Contents for 5BPU0-02C
Page 1: ...Air to Water Heat Pump Split Type R410A 50Hz 5BPU0 02D Replaces 5BPU0 02C P No MFL66101112 ...
Page 3: ...General Information THERMA V Split Type 1 Model Line Up 2 Nomenclature ...
Page 9: ...Indoor Unit THERMA V Split Type Hydro Box Unit DHW Tank Integrated Unit ...
Page 17: ...8 THERMA V Split Type Hydro Box Unit 4 Wiring Diagrams AHNW16606A3 HN1616 NK3 ...
Page 18: ...4 Wiring Diagrams 9 THERMA V Split Type Hydro Box Unit AHNW16809A3 HN1639 NK3 ...
Page 31: ...THERMA V Split Type 4 Wiring diagrams 8 DHW Tank Integrated Unit Indoor unit Controller ...