Plug-in control
63
GA 05.141/6.02 - 07/2003
Programming menu
Stop
Data to Eeprom?
Prog=yes Esc=no
Prog
Ready
00.0 A
0000 Hz
Esc
Data are stored
in the EPROM
To exit the programming menu
Via X14
Purge ON
Set Pump
Enter
Normal Operation
95 %
Enter
Max. Accel. time
1000 s
Enter
Set TMS
Enter
TMS Setpoint
70
°
C
Enter
Set Purge/Vent
Enter
Purge/Vent
Purge OFF
Enter
Option P/V
Option 1
Enter
or
Key
Function
Esc
• Returns to the operating display from the storage procedure
without storage.
• Returns to the operating display from any point of the basic
menu.
Mon
• No function
Prog
• Selects the programming menu from the operating display.
• Confirms to store changed parameters to the EEPROM
Enter
• Switches forward to the next submenu
Start
• Starts the pump (only possible if there is no fault).
The start key is only active if the user is in the basic menu
or in the operating display.
Stop
• Stops the pump (only from basic menu)
• Returns to the operating display from the programming menu.
• Acknowledges a failure after the cause of the failure has
been removed (only possible, if the user is in the operating
display).
+
• Increases a parameter value or proceeds to the next option.
–
• Lowers a parameter value or returns to the previous option.
<
• Selects the programming menu from the operating display.
• Switches back to the last main menu.
>
• Selects the programming menu from the operating display.
• Switches forward to the next main menu.
or
or
Mains Down
Powersupply OK
Start Command
Freq. Setpoint
Pump Stand Still
Enter
Threshold
70
°
C
Enter
Threshold
10.0 A
Enter
Threshold
300 Hz
Enter
P/N Analog Out
3 Param
Enter
Scaling Ana Out
1.00
Enter
Start Delay
0 s
Enter
Enter
Relay 8 Option
Start Command
Enter
Relay 9 Option
Mains Down
Enter
Relay 7 Option
Pump Stand Still
Venting
TMS OK
No Purgegas
No Cooling Water
Frequency
Set Converter
Enter
Motor Current
Relay 6 Option
Bearing Temp.
Enter
Analog Input 2
No Function
German
Enter
Bus Adress
0
Enter
Display
English
r (read)
= value can only be read
r /w (read/write) = value can be read and written
on (online)
= value can be changed always
off (offline)
= value can only be changed when the pump stands still
New: All menus can be invoked at all times for each operating mode; in
part they may be modified during operation.