Action
Yes
No
1
From the control panel, touch
Help
>
Supplies Guide
.
2
Measure the distance between the defects.
•
If the distance between the defects equals 43.90 mm
(1.73 in.), or 45.50 mm (1.79 in.), then call customer
support to replace the developer unit of the color
where defects are seen.
•
If the distance between defects of a single color equals
94.20 mm (3.7 in.), 29.80 mm (1.17 in.), or 25.10 mm
(0.99 in.), then replace the imaging unit or imaging kit.
•
If the distance between the defects equals 37.70 mm
(1.48 in.), 78.50 mm (3.09 in.), or 55.0 mm (2.17 in.), then
replace the transfer module.
•
If the distance between defects of all colors equals
95.0 mm (3.74 in.), 110 mm (4.33 in.), or 34.60 mm
(1.36 in.), then replace the fuser.
Do the repeating defects still appear?
service
representative.
The problem is solved.
Solid color or black images
Action
Yes
No
a
Remove, and then reinstall the imaging unit or imaging kit.
Warning—Potential Damage:
Do not expose the imaging unit
or imaging kit to direct light for more than 10 minutes.
Extended exposure to light may cause print quality problems.
Warning—Potential Damage:
To avoid damage, do not touch
the underside of the imaging unit or imaging kit.
b
Resend the print job.
Is the printer still printing solid color or black images?
Contact
The problem is
solved.
Troubleshooting
118
Summary of Contents for XC4100 Series
Page 1: ...XC4100 Series User s Guide January 2016 www lexmark com Machine type s 7528 Model s 598 196 ...
Page 62: ...2 Remove the waste toner bottle 3 Remove the imaging kit Maintaining the printer 62 ...
Page 64: ...8 Insert the black toner cartridge 9 Insert the imaging kit Maintaining the printer 64 ...
Page 66: ...2 Remove the waste toner bottle 3 Remove the imaging kit Maintaining the printer 66 ...
Page 68: ...8 Insert the toner cartridges 9 Insert the new imaging kit Maintaining the printer 68 ...
Page 97: ...4 Close the duplex cover and door A Clearing jams 97 ...
Page 137: ...5 ISP extended cable 4 Install the ISP into its housing Upgrading and migrating 137 ...
Page 138: ...5 Attach the housing to the controller board access cover Upgrading and migrating 138 ...
Page 144: ...5 Open door B 6 Open door C Upgrading and migrating 144 ...
Page 158: ...wireless network Wi Fi Protected Setup 55 Wi Fi Protected Setup wireless network 55 Index 158 ...