PROFINET interface
79
AMS 348
i
Leuze electronic
9.9.3.24 Module 9: Error handling procedures
PROFINET module identifier
Module-ID 1009
Submodule-ID 1
Description
The module makes parameters available to handle any errors should they occur.
In the event of a temporary error in the value/velocity calculation (e.g. plausibility error
caused by light beam interruption) the laser measurement system transmits the last valid
measurement value for a length of time xx which is to be configured.
If the configured time is exceeded, the error display or the faulty measurement value output
is activated.
Parameters
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Position value
in the case of
error
Specifies which position value is to be
output in the event of an error after the
position suppression time has elapsed.
0.0
Bit
0: Last valid value
1: Zero
1
mm
in/100 –
No function.
0.1
Bit
Always 0
0
–
–
Suppress
position sta-
tus
Specifies whether the PLB status bit is
set immediately in the event of an error
or if it is suppressed for the configured
position suppression time.
0.2
Bit
0: OFF
1: ON
1
–
–
Error delay
(position)
Specifies in the event of an error
whether the position value immediately
outputs the value of the "position value
in the case of error" parameter or out-
puts the last valid position value for the
duration of the configured "error delay
time".
0.3
Bit
0: OFF
1: ON
1
–
–
Error delay
time (posi-
tion)
Errors which occur are suppressed for
the configured time. If no valid position
value can be ascertained during the
configured time, the last valid position
value is output. If the error persists after
the time elapses, the value stored in the
"position value in the case of error"
parameter is output.
1…2
unsign
16 bit
100 … 1000
100
ms
–
Velocity in the
case of error
Specifies which velocity is to be output
in the event of an error after the velocity
suppression time has elapsed.
3.0
Bit
0: Last valid value
1: Zero
1
–
–
No function.
3.1
Bit
Always 0
0
–
–
Suppress
velocity
status
Specifies whether the PLB status bit is
set immediately in the event of an error
or if it is suppressed for the configured
velocity suppression time.
3.2
Bit
0: OFF
1: ON
1
–
–
a
b
c
d
e
f