PROFINET interface
69
AMS 348
i
Leuze electronic
9.9.3.17 Module 2: Static preset
PROFINET module identifier
Module-ID 1002
Submodule-ID 1
Description
With this module, a preset value can be specified. The specified preset value becomes active
in the position in which preset teaching is performed.
Notice!
In the event of a device change the preset value is retained in the PROFINET manager. The
activation of the preset value (preset teach) at the intended position must, however, be
performed again.
Parameters
Input data
None
Output data
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Preset
Preset value.
The value is accepted during a corre-
sponding teach event (see output data).
The resolution of the preset value is
independent of the resolution selected in
module 1.
0
sign
32 bit
-999999 … +999999
0
mm
in/100
2b
4d
5d
Parameter length: 4 bytes
a
Output data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Preset teach
Read in the preset value.
0.0
Bit
0
1 Preset teach
–
–
4d
5d
Preset reset
Preset value is deactivated.
0.1
Bit
0
1 Preset reset
–
–
4d
5d
Output data length: 1 byte
b
c