Diagnostics and troubleshooting
93
AMS 348
i
Leuze electronic
10.1
Service and diagnostics in the display of the AMS 348
i
In the main menu of the AMS 348
i
, expanded "Diagnostics" can be called up under the
Service
heading.
From the
Service
main menu, press the enter button
to access the underlying menu
level.
Use the up/down buttons
to select the corresponding menu item in the selected level;
use the enter button
to activate the selection.
Return from any sublevel to the next-higher menu item by pressing the ESC button
.
10.1.1
Status messages
The status messages are written in a ring memory with 25 positions. The ring memory is
organized according to the FIFO principle. No separate activation is necessary for storing
the status messages. Power OFF clears the ring memory.
The status messages within the ring memory are selected with the up/down buttons
.
Use the enter button
to call up detailed information about the respective status message
that includes the following details:
Type:
Designates the message type
I
= info;
W
= warning,
E
= error.
No:
Internal
numbering
Ref.
:
Plain-text explanation of the displayed status
Time:
Time stamp in the hh.mm format. The displayed time is added to the time since
the last power ON. Power OFF clears the time stamp.
10.1.2
Diagnostics
The diagnostics function is activated by selecting the
Diagnostics
menu item. The ESC
button
deactivates the diagnostics function and clears the contents of the recordings.
The recorded diagnostic data are displayed in 2 fields. In the upper half of the display, status
messages of the AMS and the bar graph are displayed. The lower half contains information
that assists in a Leuze-internal evaluation.
Service
Status messages
Diagnostics
Expanded diagnostics
ESC
Status messages
1: - / - / -
2: - / - / -
3: - / - / -
ESC