PROFINET interface
73
AMS 348
i
Leuze electronic
9.9.3.20 Module 5: I/O 2 Input/Output
PROFINET module identifier
Module-ID 1005
Submodule-ID 1
Description
The module defines the mode of operation of the digital input/output
I/O 2
.
Parameters
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Function
The parameter defines whether
I/O 2
functions as an input or as an output.
0.0
Bit
0: Input
1: Output
1
–
5cd
Activation
The parameter defines the level of the
output when the "output" event is
received. If
I/O 2
is configured as an
input, the response is edge-controlled.
0.1
Bit
0: Low
1-0 transition
1: High
0-1 transition
0
–
–
Output
The parameter defines which event trig-
gers activation of the output. The individ-
ual functions are
OR
-linked to one
another.
–
5a
Position limit value 1
If the position value lies outside of con-
figured limit range 1, the output is set.
1.0
Bit
0 = OFF
1 = ON
0
–
Position limit value 2
If the position value lies outside of con-
figured limit range 2, the output is set.
1.1
Bit
0 = OFF
1 = ON
0
–
Velocity limit value
If the velocity value lies outside of the
configured values, the output is set.
Monitoring from modules 11 to 15 is OR-
linked.
1.2
Bit
0 = OFF
1 = ON
0
–
Intensity (ATT)
If the intensity of the received signal is
less than the warning threshold, the
output is set.
1.3
Bit
0 = OFF
1 = ON
1
–
Temperature (TMP)
If the internal device temperature
exceeds the set limit value, the output is
set.
1.4
Bit
0 = OFF
1 = ON
1
–
Laser (LSR)
Laser prefailure message.
1.5
Bit
0 = OFF
1 = ON
1
–
Plausibility (PLB)
If implausible measurement values are
diagnosed, the output is set.
1.6
Bit
0 = OFF
1 = ON
0
–
a
b
c