PROFINET interface
75
AMS 348
i
Leuze electronic
9.9.3.21 Module 6: Status and control
PROFINET module identifier
Module-ID 1006
Submodule-ID 1
Description
The module signals various status information of the AMS 348
i
. The laser can be controlled
via the master's output data.
Parameters
None
Input data
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Laser
status
Signals the laser status.
1.0
Bit
0: Laser ON
1: Laser OFF
–
–
–
Preset
status
Status of the preset value.
1.1
Bit
0: Preset not active
1: Preset active
–
–
–
Preset teach
This bit toggles on each teach event of a
preset value.
1.2
Bit
0 or 1
–
–
–
Reserved
1.3
Bit
–
–
–
Intensity
(ATT)
If the intensity of the received signal is
less than the warning threshold, the
status bit is set.
1.4
Bit
0: OK
1: Warning
–
–
–
Temperature
(TMP)
If the internal device temperature
exceeds or drops below the set limit
value, the status bit is set.
1.5
Bit
0: OK
1: Temperature above/below
limit
–
–
–
Laser (LSR)
Laser prefailure message.
1.6
Bit
0: OK
1: Laser warning
–
–
–
Plausibility
(PLB)
If implausible measurement values are
diagnosed, the status bit is set.
1.7
Bit
0: OK
1: Implausible measurement
value
–
–
–
Hardware
(ERR)
If a hardware error is diagnosed, the
status bit is set.
0.0
Bit
0: OK
1: Hardware error
–
–
–
Lower
position limit
value 1
Signals that the value is less than lower
limit value 1.
0.4
Bit
0: OK
1: Value less than limit
–
–
–
Upper
position limit
value 1
Signals that the value is greater than
upper limit value 1.
0.5
Bit
0: OK
1: Value greater than limit
–
–
–
a
b
c
d
e
f
g
h
i
j
k