PROFINET interface
Leuze electronic
AMS 348
i
68
TNT
35/7-2
4
V
Notice!
If the
unit of measurement is changed from metric to inch
(or vice versa),
previously
entered numerical values
(e.g. for offset, preset, limit values etc.)
are not automatically
converted
. This must be performed manually!
Example:
Preset = 10000 mm -> Change from metric to inch -> Preset = 10000 inch/100
Input data
Output data
None
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Position value
Output of the current position.
0
sign
32 bit
-999999 … +999999
–
scaled
9a
Input data length: 4 bytes consistently
f