PROFINET interface
Leuze electronic
AMS 348
i
88
TNT
35/7-2
4
V
9.9.3.31 Module 16: Velocity status
PROFINET module identifier
Module-ID 1016
Submodule-ID 1
Description
This module supplies the PROFINET master with various status information for velocity
measurement.
Parameters
None
Input data
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Velocity mea-
surement
error
Signals that no valid velocity could be
ascertained.
1.0
Bit
0: OK
1: Error
–
–
–
Movement
status
Signals whether a movement >0.1 m/s is
currently being detected.
1.1
Bit
0: No movement
1: Movement
–
–
–
Movement
direction
When the movement status is activated,
this bit indicates the direction.
1.2
Bit
0: Positive direction
1: Negative direction
–
–
–
Velocity limit
value status 1
Signals that limit value 1 has been
exceeded.
1.3
Bit
0: Limit value
maintained
1: Limit value violated
–
–
11c
Velocity limit
value status 2
Signals that limit value 2 has been
exceeded.
1.4
Bit
0: Limit value
maintained
1: Limit value violated
–
–
12c
Velocity limit
value status 3
Signals that limit value 3 has been
exceeded.
1.5
Bit
0: Limit value
maintained
1: Limit value violated
–
–
13c
Velocity limit
value status 4
Signals that limit value 4 has been
exceeded.
1.6
Bit
0: Limit value
maintained
1: Limit value violated
–
–
14c
Dynamic
velocity limit
value status
Signals that the dynamic limit value has
been exceeded.
1.7
Bit
0: Limit value
maintained
1: Limit value violated
–
–
15bd
Velocity
comparison
limit value 1
Signals whether the current velocity is
compared with this limit value.
0.3
Bit
0: Comparison not active
1: Comparison active
–
–
–
Velocity
comparison
limit value 2
Signals whether the current velocity is
compared with this limit value.
0.4
Bit
0: Comparison not active
1: Comparison active
–
–
–
a
b
c
d
e
f
g
h
i
j