Appendix
Code table
l
94
LDEDS−CCU210B EN 4.0
Description
Possible settings
Code
Selection
Lenze
Byte
<
ñò
No.
C0257
RW
EXT
4
5.0
HWC control limitation (± of
setpoint frequency)
^
1.0
{Hz}
10.0
C0258
RW
EXT
2
200
HWC maximum system deviation
^
2
{mm}
5000
C0261
RW
EXT
2
1000
Encoder constant
^
50
{inc/m}
5000
C0264
RW
EXT
4
1.5
Voltage control V−boost minimum
^
1
{%}
25.5
C0265
RW
EXT
4
5.0
Voltage control V−boost maximum
^
4
{%}
25.5
C0351
R
_
1
0
CAN baud rate
0
500 kbps
1
250 kbps
2
125 kbps
C0390
RW
4
Reserved
C0401
0
Configuration:
response of the non−equivalence
monitoring at the digital inputs
^
1 RW
EXT
1
0
0
255 Non−equivalence monitoring 1
2
0
Non−equivalence monitoring 2
3
0
Non−equivalence monitoring 3
4
0
Non−equivalence monitoring 4
Possible values
0
Error in the case of unequal levels at
DINx
1
Error in the case of equal levels at
DINx
C0402
Configuration of non−equivalence
monitoring of the digital inputs
^
1 RW
EXT
1
0
0
255 Non−equivalence monitoring 1
2
0
Non−equivalence monitoring 2
3
0
Non−equivalence monitoring 3
4
0
Non−equivalence monitoring 4
Possible values
For the non−equivalence monitoring
only two digital inputs can be used
each.
Add values of the inputs monitored
and enter in C0402/x:
e. g. non−equivalence monitoring
for DIN3 and DIN5 = 20.
0
No monitoring
1
DIN1
2
DIN2
4
DIN3
8
DIN4
16
DIN5
32
DIN6
64
DIN7
128
DIN8