Technical data
Rated data
l
21
LDEDS−CCU210B EN 4.0
4.2
Rated data
)
Note!
The frequency inverter is not suitable for permanent operation in generator
mode.
Mains voltage
Voltage range
U
N
3/PE/PEN AC 360 V − 0 % ... 528 V + 0 %
Frequency
f
N
45 Hz − 0 % ... 65 Hz + 0 %
Fusing
10 A−T/AC 500 V
Frequency inverter (data for operation on 3/PE/PEN AC 400 V, switching frequency 8 kHz)
Starting current
Effektive
I
eff
[A]
4
Peak
I
peak
[A]
6
Rated power (typical MOC application)
Operating time 70 %
P
N
[kW]
0.75
1.5
−
Operating time 50 %
P
N
[kW]
−
−
2.2
Typical motor power
4−pole asynchronous motor, Y connection
P
N
[kW]
−
−
2.2
Max. output power
S
N
[kVA]
1.3
2.0
3.9
Output current
Duration
I
N
[A]
1.8
3.5
5.6
For 60 s
I
max
[A]
3.0
5.0
10
Switching frequency
Optionally
f [kHz]
2, 4, 8
Lenze setting
f [kHz]
8
Motor output frequency
f [Hz]
0 ... 120 variable
Power loss at rated load
P
V
[W]
22
60
100
Power loss in idle state (only half wave
power, 24V−sensors are not connected)
P
V
[W]
6
6
6
DC motor brake control
Brake voltage
Duration (U = U
N
x 0.45)
U [V DC
eff
]
185 (for U
N
= 400 V AC)
Peak (U
peak
= U
N
x
Ö
2)
U
peak
[V DC]
564 (for U
N
= 400 V AC)
Max. braking current
I [A
eff
]
0.5 ± 10 %
Integrated switched−mode power supply (supply for external encoders and actuators)
Output voltage
U
A
[V DC]
+24 (21.6 ... 26.4 V DC)
Max. output current
(current−limited)
I
A
[A DC]
0.5
0.7
0.7
Weight
Control system complete, without counter
plug
[approx. kg]
2.8
3.4
5.0