Function library
Status messages
l
75
LDEDS−CCU210B EN 4.0
8.12
Status messages
By means of the status messages you are quickly provided with an overview of the vehicle
control system status.
Codes for parameter setting
Code
Possible settings
Description
No.
ñò
<
Byte Lenze
Selection
C0050
R
4
Current drive frequency
^
75
0
{Hz}
120.0
C0053
R
4
Current DC−bus voltage
^
75
0
{V}
1000
C0054
R
4
Current motor current
^
75
0
{A}
20.0
C0056
R
4
Current output stage temperature
^
75
0
{°C}
255
C0179
R
INT
4
Power−on time
^
75
0
{min}
7884000
C0180
R
1
Seconds counter
^
75
0
{s}
59
C0183
Limit values of the DC−bus voltage
^
75
1
R
4
0
{V}
1000 Minimum
2
Maximum
C0184
Limit values of the current value
^
75
1
R
INT
4
0
{A}
20.0 Reserved
2
Maximum
C0186
Limit values of the output stage
temperature
^
75
1
R
INT
4
0
{°C}
255 Minimum
2
Maximum
C0196
R
INT
4
Average output stage temperature
^
75
0
{°C}
255