Function library
Digital input signals
Assignment logic
l
46
LDEDS−CCU210B EN 4.0
8.3.3
Assignment logic
In the assignment logic (C0410) you assign digital signal sources, like for instance digital
inputs or linkage results, to the internal control functions. By this, you define the desired
control functions and responses to specific events.
Codes for parameter setting
Code
Possible settings
Description
No.
ñò
<
Byte Lenze
Selection
C0410
Linking digital input signals to an
internal device function ...
^
46
1 RW
EXT
4
0
Not assigned
... Motor V1 (incl. brake)
2
0
Not assigned
... Motor V2 (incl. brake)
3
0
Not assigned
... Motor V3 (incl. brake)
4
0
Not assigned
... Motor V4 (incl. brake)
5
0
Not assigned
... Motor V5 (incl. brake)
6
0
Not assigned
... Motor V6 (incl. brake)
7
0
Not assigned
... Motor V7 (incl. brake)
8
0
Not assigned
... Motor V8 (incl. brake)
9
0
Not assigned
... CW/CCW rotation of motor
l
CW rotation = LOW
l
CCW rotation = HIGH
10
0
Not assigned
Reserved
11
0
Not assigned
... Set fault
12
0
Not assigned
...Acknowledge fault
13
0
Not assigned
... Frequency inverter: change over
parameter set
l
Parameter set 1 = LOW
l
Parameter set 2 = HIGH
14
0
Not assigned
... DC−injection braking
15
0
Not assigned
... Open brake
16
0
Not assigned
... Stop1
17
0
Not assigned
... Stop2
18
0
Not assigned
... Stop3
19
0
Not assigned
... Stop4
20
0
Not assigned
... Frequency limitation 1
21
0
Not assigned
... Frequency limitation 2
22
0
Not assigned
... Frequency limitation 3
23
0
Not assigned
... Frequency limitation 4
24
0
Not assigned
... SensoPart: change over
parameter set
l
Parameter set 1 = LOW
l
Parameter set 2 = HIGH
25
0
Not assigned
... Deactivate control