Appendix
Code table
l
105
LDEDS−CCU210B EN 4.0
Description
Possible settings
Code
Selection
Lenze
Byte
<
ñò
No.
C0451
RW
EXT
4
0
"Open brake" function:
maximum activation time
^
0
{s}
1000
l
C0451 = 0 s:
– Brake opens if
C0410/15 = HIGH
– Brake closes if
C0410/15 = LOW
l
C0451 > 0 s:
– Brake opens if
C0410/15 = HIGH
– Brake closes after the time set
if C0410/15 = HIGH
C0460
RW
EXT
4
1
SensoPart:
configuration
^
0
SensoPart inactive
1
SensoPart active − 57.6 kBaud
2
SensoPart active − 62.5 kBaud
3
SensoPart active − 38.4 kBaud
4
SensoPart active − 19.2 kBaud
5
SensoPart active − 9.6 kBaud
6
SensoPart active − 4.8 kBaud
C0461
RW
EXT
4
500
SensoPart:
distance for quick disconnection
^
0
{mm}
65535
C0462
SensoPart:
stop distance in ...
^
1 RW
EXT
4
2000
0
{mm}
65535 ... Parameter set 1
2
2000
... Parameter set 2
C0463
SensoPart:
hysteresis for stop distance in ...
^
1 RW
EXT
4
100
0
{mm}
65535 ... Parameter set 1
2
100
... Parameter set 2
C0464
SensoPart:
traverse path with creeping speed
VS in ...
^
1 RW
EXT
4
50
0
{mm}
65535 ... Parameter set 1
2
50
... Parameter set 2
C0466
SensoPart:
drive frequency for creeping speed
VS in ...
^
1 RW
EXT
4
5.0
0
{Hz}
120.0 ... Parameter set 1
2
5.0
... Parameter set 2
C0467
SensoPart:
delay time:
start of the acceleration V0
ð
VS in
...
^
1 RW
EXT
4
1000
0
{ms}
20000 ... Parameter set 1
2
1000
... Parameter set 2
C0468
SensoPart:
deceleration ramp for stop VS
ð
V0
in ...
^
1 RW
EXT
4
50
1
{Hz/s}
255 ... Parameter set 1
2
50
... Parameter set 2