Function library
Operating mode
l
41
LDEDS−CCU210B EN 4.0
8.2
Operating mode
The vehicle control system is operated in the "V/f characteristic control" operating mode.
Codes for parameter setting
Code
Possible settings
Description
No.
ñò
<
Byte Lenze
Selection
C0015
RW
EXT
4
0
Operating mode
^
41
0
V/f characteristic control
1
Reserved
2
Reserved
C0016
RW
EXT
4
400
Mains voltage
^
41
0
{V}
480
C0017
RW
EXT
4
0
Mains frequency
^
41
0
50 Hz
1
60 Hz
C0018
Switching frequency of the inverter
in ...
^
41
1 RW
EXT
4
2
8 kHz
... Parameter set 1
2
2
8 kHz
... Parameter set 2
Possible values
0
2 kHz
1
4 kHz
2
8 kHz
C0024
V/f characteristic – U-boost voltage
in ...
^
41
1 RW
EXT
4
5.0
1
{%}
25.5 ... Parameter set 1
2
5.0
... Parameter set 2
C0029
V/f characteristic – base frequency
in ...
^
41
1 RW
EXT
4
50.0
0
{Hz}
120.0 ... Parameter set 1
2
50.0
... Parameter set 2