Troubleshooting and fault elimination
Status display
l
79
LDEDS−CCU210B EN 4.0
Standard displays
Standard displays during operation (C0500 = 0)
Pos.
Display
Description
1
8.
8.
8.
8.
Power−up display for 0.5 s
2.
3
4
Software version for 0.5 s
f
8
8
8
Error message (blinking)
h
8
8
8
Warning signal (blinking)
I
n
h
Controller inhibit active (C0040)
o
f
f
ON/OFF switch in OFFposition
P
A
R
Parameters are saved in the EEPROM
P
d
A
Manual PDA operation via IrDA active
I
R
C
Manual infrared operation active
1
V1 forwards active
2
V2 forwards active
3
V3 forwards active
4
V4 forwards active
5
V5 forwards active
6
V6 forwards active
7
V7 forwards active
8
V8 forwards active
1
−
V1 backwards active
2
−
V2 backwards active
3
−
V3 backwards active
4
−
V4 backwards active
5
−
V5 backwards active
6
−
V6 backwards active
7
−
V7 backwards active
8
−
V8 backwards active
R
8.
8
8
Vv (variable frequency selection HWC Code Range) forward active
d
Starting delay function active
P
o.
8
8
IrDA positioning active
P
o. −| |−
IrDA positioning − position reached
1
1
’
SensoPart: parameter set 1 active
2
’ ’
SensoPart: parameter set 2 active
B
o
"Open brake" active
s
1.
Stop 1 active
s
2.
Stop 2 active
s
3.
Stop 3 active
s
4.
Stop 4 active
s
d.
SensoPart: stop distance active
s
e.
SensoPart: stop "Emergency distance" active
l
b.
SensoPart: creeping speed active
l
d.
SensoPart: approach speed active
l
1.
Frequency limitation 1 active
l
2.
Frequency limitation 2 active
l
3.
Frequency limitation 3 active
l
4.
Frequency limitation 4 active
8
8
Current drive frequency [Hz]