Network setpoint
•
In order to generally set the network as standard setpoint source, go to
0x2860:001
(PAR 201/001)
and select "Network [5]".
•
If a bit of the mappable NETWordIN1 data word is to be used for activation, use
0x400E:001
(PAR 505/001)
to assign the function "Setpoint = Network [17]" to the corresponding bit of
NETWordIN1.
•
There is no specific function with a selectable trigger for a setpoint change-over to the net-
work.
Parameter
Name / value range / [default setting]
Info
0x231F:001
(PAR 500/001)
Module ID: Active module ID
(Module ID: Active module ID)
•
Read only
•
Default setting depending on the size.
Display of the network options currently configured in the inverter.
•
When the "Load Lenze settings" device command
0x2022:001
(PAR 700/001)
or "Accept new inverter hardware"
0x2022:027
(PAR 700/027)
is executed, the module ID is stored in the memory
module.
•
With the help of this module ID, the keypad only shows the communi-
cation parameters relevant to the respective network.
0 No network
67 CANopen
80 PROFIBUS
87 Modbus
0x231F:002
(PAR 500/002)
Module ID: Module ID connected
(Module ID: Module ID conn.)
•
Read only
Display of the network options currently connected in the inverter.
0 No network
67 CANopen
80 PROFIBUS
87 Modbus
0x400E:001
(PAR 505/001)
NETWordIN1 function assignment: Bit 0
(NETWordIN1 config.: NETWordIN1.00)
•
Setting can only be changed if controller inhibit is
active.
Definition of the function that is to be triggered via bit 0 of the mappa-
ble NETWordIN1 data word.
0 Not active
Trigger bit without any function.
1 Controller inhibit
Trigger bit = 0-1 edge: The inverter is inhibited. Starting the drive is not
possible.
Trigger bit = 0: The inverter is enabled (unless there is another cause for
controller inhibit).
Notes:
•
In all device states, a 0-1 edge causes an immediate change to the
inhibited state with one exception: If the inverter is in the error status
and the error condition still exists, the inverter remains in the error
status.
•
Changing to the inhibited state causes an immediate stop of the drive,
regardless of the stop method set in
0x2838:003 (PAR 203/003)
. The
drive coasts down as a function of the mass inertia of the machine.
•
After deactivating the controller inhibit, a new start command is
required to restart the drive.
•
The causes that are active for controller inhibit are shown in
0x282A:
001 (PAR 126/001)
.
2 Stop
Trigger bit = 1: Drive is stopped.
Trigger bit = 0: No action / Deactivate stop again.
Notes:
•
The stop method can be selected in
0x2838:003 (PAR 203/003)
.
3 Quick stop
Trigger bit = 1: "Quick stop" function activated.
Trigger bit = 0: no action / deactivate function again.
Notes:
•
The "Quick stop" function brings the motor to a standstill within the
deceleration time set in
0x291C (PAR 225)
.
•
The "Quick stop" function has a higher priority than the "Start enable"
function.