5.3.2
Error history buffer
For purposes of diagnostics, the error history buffer contains the last 32 error and warning
messages of the inverter, which have occurred during operation. The error history buffer can
be read out using the keypad via PAR 155 and provides a limited view on the logbook.
Details
•
For each event that is recorded, the error history buffer contains the message text, the error
code, the time of occurrence as well as a counter for successive, identical events. If an event
that has already been recorded occurs repeatedly, only the counter is incremented.
•
The error history buffer can be reset by the user. In order to prevent the buffer from being
reset by the user, this function can be protected by means of a password.
•
Observe that the error history buffer only presents a snapshot at the time the data are read
out. If a new event occurs, the error history buffer must be read out again via PAR 155 so
that the new event becomes visible.
Accessing the error history buffer with the keypad
S T O P
MAN
AUTO SET
LOC
REM
0 1 W F F 1 5
MAN
AUTO SET
LOC
REM
W.UV dc link
G R O U P 0
MAN
AUTO SET
LOC
REM
Favorites
P A R 1 0 0
MAN
AUTO SET
LOC
REM
Actual frequency
1.
2.
3.
4.
5.
6.
VEL:FLEX:AIN1
P A R 1 5 5
MAN
AUTO SET
LOC
REM
Diag History
G R O U P 1
MAN
AUTO SET
LOC
REM
Diagnostics
0 0 1
MAN
AUTO SET
LOC
REM
Time 01d17h04m00s
:
0 1 C
1. Use the key in the operating mode to navigate to the
parameterisation mode one level below.
You are now in the group level. All parameters of the
inverter are divided into different groups according to
their function.
Note: Use the key to navigate one level upwards
again anytime.
2. Use the navigation key to select group 1 ("Diagnos-
tics").
3. Use the key to navigate to one level below.
You are now in the parameter level of the group selec-
ted.
4. Use the and navigation keys to select the PAR 155
parameter.
5. Use the key to navigate to one level below.
You are now in the error history buffer.
6. With the and navigation keys you can now scroll
through the fault memory entries.
By means of the key, you can switch over the display.
Information displayed (page 1):
❶
Message text
❷
Error memory entry (01 = most recent event)
❸
Response (W = warning, T = trouble, F = fault)
❹
Error code
Information displayed (page 2):
❺
Time of occurrence
❻
Error memory entry (01 = most recent event)
❼
Counter for successive, identical events
Note: By using the key you can exit the error history
buffer again.
Parameter
Name / value range / [default setting]
Info
0x2006:000
(PAR 155/000)
Error history buffer: Keypad display
(Fault memory: Keypad display)
•
Read only
Display of the error history buffer on the keypad.
0x2006:001
Error history buffer: Maximum number of messages
•
Read only
Display of the maximum number of messages which can be stored in the
history buffer (from subindex 6).
0x2006:002
Error history buffer: Latest message
•
Read only
Display of the subindex of the most recent message.