EDS94AYCCA EN 5.0 - 06/2012
L
169
E94AYCCA communication manual (CANopen®)
Implemented CANopen objects
I-1400 - RPDO1 communication parameter
Communication parameter for the reception of process data via RPDO1
[14-15] Data telegram assignment
How to change the identifier:
1. Deactivate identifier (set bit 31 to "1").
2. Change identifier.
3. Activate identifier (set bit 31 to "0").
Index:
I-1400
Name:
RPDO1 communication parameter
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
5
- (only read access)
ro
U8
1: COB-ID used by RPDO
0x200 + node ID
0
4294967295 rw
U32
2: transmission type
254
0
255 rw
U8
3: inhibit time
-
- (for RPDOs unused)
rw
U16
4: compatibility entry
-
- (reserved, write or read access results in error
message 0x06090011)
rw
U8
5: event timer
-
- (for RPDOs unused)
rw
U16
Subindex
Meaning
Lenze code
1
Identifier RPDO1
• The basic setting is according to the
"Predefined Connection Set": Identifier = 0x200 +
node ID
/
2
RPDO transmission type according to DS301, V4.02
/
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
Bit 31
Bit 30
Bit 29 ... bit 11
Bit 10 ... bit 0
0/1
0/1
Extended identifier*
11-bit identifier
* The extended identifier is not supported - bit 11 ... bit 29 must be set to "0".
Bit
Setting
Bit 30
0 RTR to this PDO possible (cannot be set).
1 RTR to this PDO not possible (Lenze).
Bit 31
0 PDO active.
1 PDO inactive.