EDS94AYCCA EN 5.0 - 06/2012
L
163
E94AYCCA communication manual (CANopen®)
Implemented CANopen objects
I-1018 - Identity object
I-1029 - Error behaviour
This object serves to set the communication status to which the controller is to change
after a bus-off, a node/life guarding event or a heartbeat event.
Index:
I-1018
Name:
Identity object
Subindex
Default setting
Display range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
see below
0
4294967295 ro
U32
1: Vendor ID
2: Product code
3: Revision number
4: Serial number
Subindex
Meaning
1
Manufacturer identification number
• The identification number allocated to Lenze by the "CAN in Automation e. V."
organisation is "0x0000003B".
2
Product code
0x94001 9400 StateLine
0x94002 9400 HighLine / ServoPLC
0x94004 9400 regenerative power supply module
3
Main version and subversion of the firmware
4
Serial number
Index:
I-1029
Name:
Error behaviour
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
1
- (only read access)
ro
U8
1: Communication error
0
0
2 rw
U8
Subindex
Meaning
Lenze code
1
Status change after bus off, node/life guarding event or
heartbeat event:
0 State change from "Operational" to "Pre-
operational"
1 No state change
2 State change to "Stopped"