Table 3. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSFIO0034J
PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay
number [arg3].
Warning
FQXSFMA0012L
The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
Warning
FQXSFMA0016M
Memory spare copy failed. [arg1]
Warning
FQXSFMA0026G
Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR)
Warning
FQXSFMA0027M
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M
DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
FQXSFMA0030K
Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]%
and still functioning.
Warning
FQXSFMA0031K
Intel Optane PMEM [arg1] has reached 1% remaining spares block
and still functioning.
Warning
FQXSFMA0033M
Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning
FQXSFMA0034M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
Warning
FQXSFMA0035M
Intel Optane PMEM interleave set should have [arg1] PMEMs, but
[arg2] PMEMs are missing.
Warning
FQXSFMA0036M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set is missing.
Warning
FQXSFMA0037G
Intel Optane PMEM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated PMEMs are not
supported nor warranted in this system.
Warning
FQXSFMA0038K
All Intel Optane PMEMs could not be auto unlocked because of no
passphrase.
Warning
FQXSFMA0039K
One or more Intel Optane PMEMs could not be auto unlocked
because of invalid passphrase.
Warning
FQXSFMA0040K
Invalid Intel Optane PMEM configuration detected. Please verify
PMEM configuration is valid.
Warning
FQXSFMA0041K
Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel Optane
PMEM configuration is not in recommended range (1:[arg3] - 1:[arg4]).
Warning
FQXSFMA0047M
SPD CRC checking failed on DIMM [arg1]. [arg2]
Warning
FQXSFPU0022G
The TPM configuration is not locked.
Warning
FQXSFPU0023G
Secure Boot Image Verification Failure Warning.
Warning
FQXSFPU0033G
Processor has been disabled.
Warning
FQXSFPU0062F
System uncorrectable error happened in Processor [arg1] Core [arg2]
MC bank [arg3] with MC Status [arg4], MC Address [arg5], and MC
Misc [arg6].
Warning
138
ThinkSystem SR650 V2 Messages and Codes Reference
Summary of Contents for ThinkSystem SR650 V2
Page 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Page 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......