SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
1. Check if there is a drive failed. If yes, replace the failed drive.
2. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPUN0054M: The RAID controller in PCI slot [arg1] is in critical status. At least one logical
drive is now degraded or partially degraded.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
1. Check if there is a drive failed. If yes, replace the failed drive.
2. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPUN0055M: The RAID controller in PCI slot [arg1] is in critical state. Battery is in non-optimal
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
1. Check whether a RAID battery is installed and attached.
2. If no RAID battery is installed, please ignore this message.
3. If a RAID battery is installed, check the RAID battery for air flow obstruction and ensure that battery
cables are properly connected.
4. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPUN0057I: The RAID controller in PCI slot [arg1] does not have a battery.
This message is for the use case when an implementation has detected a RAID controller does not have a
battery.
Severity: Info
Serviceable: No
Automatically notify Support: No
.
127
Summary of Contents for ThinkSystem SR650 V2
Page 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Page 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......