Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
5. If the problem persists, please contact technical support.
•
FQXPMOS0002K: Failed to read Deployment Manager Signature from USB.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. If the problem persists, reflash BMC firmware.
4. Retry OS deployment.
5. If the problem persists, perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
•
FQXPMOS0003K: Failed to copy Windows boot files to target
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. Reflash BMC firmware.
4. Retry OS deployment.
5. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
•
FQXPMOS0004K: BMC Communication Failed: EMMC2USB Mount Failure.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. Reflash BMC firmware.
4. Retry OS deployment.
5. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
•
FQXPMOS0005K: BMC communication failed: DRIVER Mount Failure.
Severity: Warning
188
ThinkSystem SR650 V2 Messages and Codes Reference
Summary of Contents for ThinkSystem SR650 V2
Page 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Page 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......