Table 1. Events that automatically notify Support (continued)
Event ID
Message String
FQXSPIO0011N
An Uncorrectable Error has occurred on [SensorElementName].
FQXSPIO0015M
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
FQXSPPW0002L
[PowerSupplyElementName] has Failed.
FQXSPPW0035M
Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
FQXSPPW0047M
Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
FQXSPSD0001L
The [StorageVolumeElementName] has a fault.
FQXSPSD0002G
Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
FQXSPSD0002L
Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has a fault.
FQXSPSD0003G
Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
FQXSPSD0006L
Array [ComputerSystemElementName] has failed.
FQXSPSD0008L
Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
FQXSPSS4004I
Test Call Home Generated by user [arg1].
FQXSPSS4005I
Manual Call Home by user [arg1]: [arg2].
XCC events organized by severity
The following table lists all XCC events, organized by severity (Information, Error, and Warning).
Table 2. Events organized by severity
Event ID
Message String
Severity
FQXSPBR4000I
Management Controller [arg1]: Configuration restored from a file by
user [arg2].
Informational
FQXSPBR4002I
Management Controller [arg1] Reset was caused by restoring default
values.
Informational
FQXSPBR4004I
Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2],
OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4],
LoaderTimeout=[arg5].
Informational
FQXSPBR4005I
Management Controller [arg1]: Configuration saved to a file by user
[arg2].
Informational
FQXSPBR4006I
Management Controller [arg1]: Configuration restoration from a file by
user [arg2] completed.
Informational
FQXSPBT0007I
No bootable media available for system
[ComputerSystemElementName].
Informational
FQXSPCA2002I
Numeric sensor [NumericSensorElementName] going low (lower
critical) has deasserted.
Informational
FQXSPCA2007I
Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has deasserted.
Informational
5
Summary of Contents for ThinkSystem SR650 V2
Page 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Page 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......