Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0252
User Action:
Information only; no action is required.
•
FQXSPPP4050I: Management Controller [arg1] reset was initiated to activate PFR Firmware.
Management Controller reset was initiated to activate PFR Firmware.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0253
User Action:
Information only; no action is required.
•
FQXSPPR0001I: [ManagedElementName] detected as absent.
This message is for the use case when an implementation has detected a Managed Element is Absent.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0392
User Action:
Complete the following steps until the problem is solved:
1. Reinstall the VGA/front panel connector and cable.
2. If the problem persists, contact Lenovo Support.
•
FQXSPPU0001N: An Over-Temperature Condition has been detected on [ProcessorElementName].
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0036
User Action:
Complete the following steps until the problem is solved:
1. Check the XCC event log for any fan or cooling related issues and address them first.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place and keep clean.
3. Make sure that the room temperature meets operating specifications.
4. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
83
Summary of Contents for ThinkSystem SR650 V2
Page 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Page 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......