v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
SeeChapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Sensor Sys Board Fault has
transitioned to critical from a less
severe state.
Error
A sensor has changed to
Critical state from a less
severe state.
1.
Check the system-event log.
2.
Check for an error LED on the
system board.
3.
Replace any failing device.
4.
Check for a server firmware
update.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5.
(Trained service technician
only) Replace the system
board.
Sensor RAID Error has transitioned
to critical from a less severe state.
Error
A sensor has changed to
Critical state from a less
severe state.
1.
Check the hard disk drive
LEDs.
2.
Reseat the hard disk drive for
which the status LED is lit.
3.
Replace the defective hard
disk drive.
The Drive
n
Status has been
removed from unit Drive 0 Status.
(
n
= hard disk drive number)
Error
A drive has been removed.
Reseat hard disk drive
n
.
(
n
= hard disk drive number)
The Drive
n
Status has been
disabled due to a detected fault.
(
n
= hard disk drive number)
Error
A drive has been disabled
because of a fault.
1.
Run the hard disk drive
diagnostic test on drive
n
.
2.
Reseat the following
components:
a.
Hard disk drive
b.
Cable from the system
board to the backplane
3.
Replace the following
components one at a time, in
the order shown, restarting
the server each time:
a.
Hard disk drive
b.
Cable from the system
board to the backplane
c.
Hard disk drive backplane
(
n
= hard disk drive number)
36
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Summary of Contents for ThinkServer TS200 6522
Page 2: ......
Page 199: ...Chapter 6 Replacing FRUs 191 ...
Page 289: ......
Page 290: ...Printed in USA ...