1
Battery
2
Battery carrier
3
RAID adapter
4
Connector for battery carrier
b.
Press the battery carrier into the connector on the ServeRAID adapter until it is firmly connected.
c.
Secure the battery carrier to the ServeRAID adapter with the screws that came with the battery
pack.
4.
Open the rear retention bracket.
5.
Turn the ServeRAID-MR10i adapter so that the ServeRAID-MR10i adapter keys align correctly with
the connector.
Attention:
Incomplete insertion might cause damage to the system board or the ServeRAID-MR10i
adapter.
6.
Take the signal cable that is attached to the drive backplane and connect it to the ServeRAID adapter.
Note:
When you restart the server, you are prompted to import the existing RAID configuration to
the new ServeRAID adapter.
7.
Press the ServeRAID-MR10i adapter firmly into the connector on the system board.
8.
Reconnect the cables to the new ServeRAID-MR10i adapter.
Removing an optional ServeRAID-MR10is VAULT SAS/SATA controller
To remove a ServeRAID-MR10is SAS/SATA adapter, complete the following steps:
1.
Read the safety information beginning on page 1.
2.
Turn off the server and peripheral devices, and disconnect the power cords and all external
cables.Remove the side cover (see “Removing the side cover” on page 130)
3.
Rotate the rear adapter-retention bracket to the open (unlocked) position.
4.
Open the rear retention bracket.
5.
Disconnect any cables connected to the adapter.
Attention:
To avoid breaking the retaining clips or damaging the ServeRAID-MR10is adapter
connector, open and close the clips gently.
6.
Carefully grasp the end of the ServeRAID adapter and pull it out of the connector.
Chapter 6. Replacing FRUs
159