v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See the parts listing in the
Hardware Maintenance Manual
to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System error or
information LED lit
Description
Action
DIMM 1 to DIMM 16
error LEDs
A DIMM has failed or is incorrectly
installed.
1.
Remove the DIMM that is indicated by a lit error
LED.
2.
Reseat the DIMM.
3.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
DIMM
b.
(Trained service technician only) System board
CPU 1 error LED
Microprocessor 1 has failed, is
missing, or has been incorrectly
installed.
Note:
(Trained service technician
only) Make sure that the
microprocessors are installed in the
correct sequence; see the procedures
for removing and installing a
microprocessor in the
Hardware
Maintenance Manual
.
1.
Check the system-event log to determine the
reason for the lit LED.
2.
(Trained service technician) Reseat the failing
microprocessor.
3.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
(Trained service technician only) Failing
microprocessor
b.
(Trained service technician only) System board
CPU 2 error LED
Microprocessor 2 has failed, is
missing, or has been incorrectly
installed.
Note:
(Trained service technician
only) Make sure that the
microprocessors are installed in the
correct sequence; see the procedures
for removing and installing a
microprocessor in the
Hardware
Maintenance Manual
.
1.
Check the system-event log to determine the
reason for the lit LED.
2.
Find the failing, missing, or mismatched
microprocessor by checking the LEDs on the
system board.
3.
(Trained service technician) Reseat the failing
microprocessor.
4.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
(Trained service technician only) Failing
microprocessor
b.
(Trained service technician only) System board
CPU mismatch LED
A mismatched microprocessor has
been installed.
Note:
All microprocessors must
have the same speed and cache
size.
1.
Run the Setup Utility and view the microprocessor
information to compare the installed
microprocessor specifications.
2.
(Trained service technician only) Remove and
replace one of the microprocessors so that they
both match.
122
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual