7.
Align the PCIe adapter card so that the keys align correctly with the connector on the system board.
Attention:
Incomplete insertion might cause damage to the system board or the PCIe adapter card.
Note:
The drive cage should be in the open position. This illustration shows it in the closed position.
8.
Press the PCIe adapter card firmly into the connector on the system board.
9.
Take the other end of the signal cable that is attached to the drive backplane section for drive bays 0
through 3 (as labeled on the front of the drive cage) and connect it to the connector that is closest to
the battery on the PCIe adapter card.
10.
Replace the hard disk drive fan assembly:
a.
Insert the hard disk drive fan assembly retaining tab over the right edge of the hard disk drive
backplane; then, rotate the hard disk drive fan assembly toward the backplane. Do not fully close
the hard disk drive fan assembly.
b.
Route the signal cables and power cable through the slot on the edge of the hard disk drive fan
assembly. Make sure that the cables will not be pinched between the hard disk drive fan
assembly and the hard disk drive backplane when the assembly is installed.
c.
Rotate the hard disk drive fan assembly toward the backplane until the release tabs are fully
engaged and snap into place.
11.
Reconnect the hard disk drive fan assembly cable to the system board.
12.
Rotate the drive cage back into the server until it stops; then, press and hold the retaining tab on top
of the drive cage while you rotate the drive cage into the chassis until it is in the closed position.
13.
Reinstall the hard disk drives.
Note:
Before you continue, check all internal power cables to make sure that they are connected to
the system board and other optional devices.
14.
Go to “Completing the FRU replacement” on page 190.
Replacing a USB embedded hypervisor flash device
Use the following procedures to replace the hypervisor flash device.
Removing a USB embedded hypervisor flash device
To remove the hypervisor flash device, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and peripheral devices and disconnect all power cords.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
4.
Unlock the USB retaining latch by squeezing the two retaining clips toward each other. Then, lift up
the bracket cover.
5.
Grasp the flash device and pull to remove it from the connector.
6.
Press down on the retaining latch to return it to the original position.
7.
If you are instructed to return the flash device, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing a USB embedded hypervisor flash device
To install the hypervisor flash device, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and all attached devices; then, disconnect all power cords.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
4.
Unlock the USB retaining latch by squeezing the two retaining clips toward each other.
Chapter 6. Replacing FRUs
161