Three boot failure
Configuration changes, such as added devices or adapter firmware updates can cause the server to fail
POST (power-on self-test). If this occurs on three consecutive boot attempts, the server will temporarily
uses the default configuration values and automatically goes to F1 Setup. To solve the problem, complete
the following steps:
1.
Undo any configuration changes that you made recently and restart the server.
2.
Remove any devices that you added recently and restart the server.
3.
If the problem remains, go to the Setup utility and select
Load Default Settings
, and then click
Save
to restore the server factory settings.
Chapter 4. Diagnostics
107