Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service
technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
201-805-xxx
Memory
Memory Test
Aborted
Test canceled: the
memory controller
display/alter write
operation was not
completed.
1.
Turn off and restart the system.
2.
Run the test again.
3.
Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 258.
4.
Run the test again.
5.
If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
201-806-xxx
Memory
Memory Test
Aborted
Test canceled: the
memory controller
fast scrub operation
was not completed.
1.
Turn off and restart the system.
2.
Run the test again.
3.
Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 258.
4.
Run the test again.
5.
If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
201-807-xxx
Memory
Memory Test
Aborted
Test canceled: the
memory controller
buffer free request
failed.
1.
Turn off and restart the system.
2.
Run the test again.
3.
Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 258.
4.
Run the test again.
5.
If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Chapter 4. Diagnostics
91