2.
Install the four screws that secure the power supply to the chassis.
3.
Connect the cables from the power supply to the system board and all internal components (see
“System-board internal connectors” on page 118 for the locations of the internal connectors).
4.
Go to “Completing the FRU replacement” on page 190.
Replacing the microprocessor and fan sink
Use the following procedures to replace the microprocessor and fan sink.
Removing the microprocessor and fan sink
To remove the microprocessor and fan sink, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
3.
Turn the server on its side so that it is lying flat, with the cover facing up.
4.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
5.
Remove the lower bezel (see “Removing the two-piece bezel” on page 131).
6.
Remove the hard disk drives.
7.
Press and hold the drive cage release tab; then, rotate the drive cage out of the chassis until the
retaining tab on top of the cage locks into place.
8.
Disconnect any cables that impede access to the fan sink and microprocessor.
Attention:
The fan-sink retention lever is spring-loaded when the fan sink is in place. Releasing the
lever too quickly or allowing it to spring upward can damage the fan sink and surrounding
components.
9.
Remove the fan sink from the microprocessor:
a.
Disconnect the fan-sink cable from the system board.
182
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual