236F00C4
Sensor Type: Watchdog
2 Event Severity: Info
Description: Time Expired
- Asserted
The watchdog timer
is expired.
It is just an information. Users don't need to
do anything.
236F01C4
Sensor Type: Watchdog
2 Event Severity: Info
Description: Hard Reset -
Asserted
The Hard Reset
is triggered by
watchdog.
It is just an information. Users don't need to
do anything.
236F02C4
Sensor Type: Watchdog
2 Event Severity: Info
Description: Power Down
- Asserted
The Power Down
is triggerred by
watchdog.
It is just an information. Users don't need to
do anything.
236F03C4
IPMI_Watchdog
Sensor Type: Watchdog
2 Event Severity: Info
Description: Power Cycle
- Asserted
The Power Cycle
is triggered by
watchdog.
It is just an information. Users don't need to
do anything.
076F01C5
076F01C6
CPU%_Status (% =
CPU number)
Sensor Type: Processor
Event Severity: Critical
Description: Thermal Trip
- Asserted
CPU temperature
is too high. At the
same time, system
will be shutdown.
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
for an applicable tip or firmware update that
applies to this error. 3. Check Fan status. if
Fan is broken, please replace the new Fan. 4.
Contact your Lenovo service representative
for support
070301C7
Sensor Type: Processor
Event Severity: Warning
Description: State
Asserted - Asserted
CPU begins to
throttle because its
temperature is too
high.
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
for an applicable tip or firmware update that
applies to this error. 3. Check Fan status. if
Fan is broken, please replace the new Fan. 4.
Contact your Lenovo service representative
for support
076F0AC7
PROC_Hot
Sensor Type: Processor
Event Severity: Warning
Description: Processor
Automatically Throttled -
Asserted
CPU begins to
throttle which is
triggered by PSU
alert.
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
for an applicable tip or firmware update that
applies to this error. 3. Check Fan status. if
Fan is broken, please replace the new Fan. 4.
Contact your Lenovo service representative
for support
CF6F00C9 Chassis_Control
Sensor Type: Customer
Sensor Type Event
Severity: Info Description:
Chassis Control -
Asserted
BMC gets "Chassis
Control" command.
It is just an information. Users don't need to
do anything.
070301D0 CPU_CATERR
Sensor Type: Processor
Event Severity: Critical
Description: State
Asserted - Asserted
Catastrophic error
happened.
1. Check the Lenovo support website for
an applicable tip or firmware update that
applies to this error. 2. Restart the server. 3.
Contact your Lenovo service representative
for support
070301D1 CPU_VR_Fault
Sensor Type: Processor
Event Severity: Critical
Description: State
Asserted - Asserted
CPU VR fault.
1. Check the Lenovo support website for
an applicable tip or firmware update that
applies to this error. 2. Restart the server. 3.
Contact your Lenovo service representative
for support
164