02010415
02010416
Sensor Type: Voltage
Event Severity: Critical
Description: Lower
Non-Recoverable - Going
Low - Asserted
CPU% DDR_VDD
voltage is too low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010215
02010216
Sensor Type: Voltage
Event Severity: Critical
Description: Lower
Critical - Going Low -
Asserted
CPU% VCORE
voltage is too low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010015
02010016
Sensor Type: Voltage
Event Severity: Warning
Description: Lower
Non-Critical - Going Low
- Asserted
CPU% VCORE
voltage is too low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010B15
02010B16
Sensor Type: Voltage
Event Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
CPU% VCORE
voltage is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010915
02010916
Sensor Type: Voltage
Event Severity: Critical
Description: Upper
Critical - Going High -
Asserted
CPU% VCORE
voltage is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010715
02010716
CPU%_DDR_VDD
(% = CPU number)
Sensor Type: Voltage
Event Severity: Warning
Description: Upper
Non-Critical - Going High
- Asserted
CPU% VCORE
voltage is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
01010B20
Sensor Type:
Temperature Event
Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
Inlet temperature is
too high
1. Check ambient temperature is within
environment spec. 2. Check the Lenovo
support website for an applicable tip or
firmware update that applies to this error. 3.
Check Fan status. if Fan is broken, please
replace the new Fan. 4. Contact your Lenovo
service representative for support
01010920
Sensor Type:
Temperature Event
Severity: Critical
Description: Upper
Critical - Going High -
Asserted
Inlet temperature is
too high
1. Check ambient temperature is within
environment spec. 2. Check the Lenovo
support website for an applicable tip or
firmware update that applies to this error. 3.
Check Fan status. if Fan is broken, please
replace the new Fan. 4. Contact your Lenovo
service representative for support
01010720
Inlet_Temp
Sensor Type:
Temperature Event
Severity: Warning
Description: Upper
Non-Critical - Going High
- Asserted
Inlet temperature is
too high
1. Check ambient temperature is within
environment spec. 2. Check the Lenovo
support website for an applicable tip or
firmware update that applies to this error. 3.
Check Fan status. if Fan is broken, please
replace the new Fan. 4. Contact your Lenovo
service representative for support
Appendix A. TMM error messages
155