SNMP Trap ID
The SNMP trap ID that is found in the SNMP alert management information base (MIB).
Automatically contact Service
If this field is set to
Yes
, and you have enabled Electronic Service Agent (ESA), Lenovo Support will be
notified automatically if the event is generated.
While you wait for IBM Support to call, you can perform the recommended actions for the event.
User response
Indicates what actions you should perform to solve the event.
Perform the steps listed in this section in the order shown until the problem is solved. After you perform
all of the actions that are described in this field, if you cannot solve the problem, contact IBM Support.
Note:
This list includes error codes and messages that might not apply to this machine type and model.
The following is the list of TMM error messages and suggested actions to correct the detected server
problems. For more information about TMM, see the
TMM User’s Guide
.
TMM error messages
Use this information to resolve any issues that were found.
Diagnostic
Code
Full Sensor Name
(Sensor Name
In SDR)
Message
Description
Action
04010401
04010402
04010403
04010404
04010405
Sensor Type: Fan
Event Severity: Critical
Description: Lower
Non-Recoverable - Going
Low - Asserted
Fan% speed is too
low.
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Check Fan status. if Fan
is broken, please replace the new Fan. 3.
Contact your Lenovo service representative
for support
04010B01
04010B02
04010B03
04010B04
04010B05
Fan%_Speed (% =
Fan number)
Sensor Type: Fan
Event Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
Fan% speed is too
high.
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010410
Sensor Type: Voltage
Event Severity: Critical
Description: Lower
Non-Recoverable - Going
Low - Asserted
12V voltage is too
low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010210
Sensor Type: Voltage
Event Severity: Critical
Description: Lower
Critical - Going Low -
Asserted
12 voltage is too
low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010010
Sensor Type: Voltage
Event Severity: Warning
Description: Lower
Non-Critical - Going Low
- Asserted
12V voltage is too
low
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
02010B10
Sensor Type: Voltage
Event Severity: Critical
Description: Upper
12V voltage is too
high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
SYS_12V
152
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide