PCI riser assembly
Adapter
Expansion-slot filler
Screw
Figure 45. PCI riser-card assembly
Read the safety information in “Safety” on page v and “Installation guidelines” on page 75.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices
and disconnect all external cables.
To replace an adapter, complete the following steps.
Note:
If your adapter was previously configured, backup or record its configuration information, if possible,
before replacing the adapter. See the documentation for your adapter for information and instructions.
Step 1.
Touch the static-protective package that contains the adapter to any unpainted metal surface on
the server; then, remove the adapter from the package.
Step 2.
Place the adapter, component side up, on a flat, static-protective surface and set any jumpers or
switches as described by the adapter manufacturer, if necessary.
Step 3.
Follow the cabling instructions, if any come with the adapter. Route the adapter cables before
you install the adapter.
Step 4.
Align the gold finger on the adapter with the connector on the PCI riser-card assembly, then, insert
the adapter into the PCI riser-card assembly. Press the edge of the connector
firmly
into the PCI
riser-card assembly. Make sure that the adapter is securely installed in the PCI riser-card assembly.
Important:
Make sure that the U-shaped opening in the metal adapter bracket engages the tab
on the expansion-slot filler.
110
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide