Step 1. Make preparations for this task.
a. Remove the top cover (see “Remove the top cover” on page 214).
b. Remove the PCIe riser (see “Remove the PCIe riser assembly” on page 157) where the flash
power module is located.
Step 2. Remove the flash power module.
Figure 51. Removing flash power module from
vertical holder
Figure 52. Removing flash power module from
horizontal holder
Press and release the retaining latch.
Rotate the flash power module away.
Remove the flash power module.
After this task is completed
• Install a replacement unit (see “Install a flash power module” on page 139).
• If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
• If you plan to remove or recycle the flash power module holder:
–
Vertical holder
.
Hardware replacement procedures
137
Summary of Contents for 7D31
Page 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Page 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Page 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Page 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Page 71: ...Chapter 3 Internal cable routing 63 ...
Page 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Page 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Page 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Page 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Page 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Page 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Page 273: ......
Page 274: ......