Operating system cannot be installed to NVMe drives that are set with Intel VROC
As Intel VROC presently does not support operating system installation, adopt one of the following options to
solve the problem.
• Disable VROC.
• Install the operating system to other types of drives, including hard disk drives or solid state drives.
Fan problems
See this section to resolve issues related the to fans.
• “Abnormally high RPM (revolutions per minute)” on page 235
Abnormally high RPM (revolutions per minute)
Complete the following procedure to solve the problem.
1. Check to see if the system inlet perforation or heat sinks are clogged.
2. Make sure that all air baffles are correctly installed in the server.
3. Check the thermal grease on the processor , and make sure it's not contaminated.
Intermittent problems
See this section to solve intermittent problems.
• “Intermittent external device problems” on page 235
• “Intermittent KVM problems” on page 235
• “Intermittent unexpected reboots” on page 236
Intermittent external device problems
Complete the following procedure to solve the problem.
1. Make sure that the correct device drivers are installed. See the manufacturer's website for
documentation.
2. For a USB device:
a. Make sure that the device is configured correctly.
Restart the server and press F1 to display the Lenovo XClarity Provisioning Manager V3 system
setup interface. Then, click
System Settings
➙
Devices and I/O Ports
➙
USB Configuration
.
b. Connect the device to another port. If using a USB hub, remove the hub and connect the device
directly to the server. Make sure that the device is configured correctly for the port.
Intermittent KVM problems
Complete the following procedure to solve the problem.
Video problems:
1. Make sure that all cables and the console breakout cable are properly connected and secure.
2. Make sure that the monitor is working properly by testing it on another server.
3. Test the console breakout cable on a working server to ensure that it is operating properly. Replace the
console breakout cable if it is defective.
Keyboard problems:
235
Summary of Contents for 7D31
Page 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Page 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Page 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Page 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Page 71: ...Chapter 3 Internal cable routing 63 ...
Page 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Page 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Page 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Page 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Page 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Page 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Page 273: ......
Page 274: ......