Network settings can not be changed
Complete the following procedure to solve the problem:
1. Go to
Setup Utility
➙
BMC Settings
➙
Network Settings
, and check if the system is configured as
following:
• In
Network Interface Port
,
Dedicated
is set.
• In
Fail-over Rule
,
Failover to Shared NIC
is set.
• In
Failed over to Shared NIC
➙
Network Settings
,
Independence
is set.
2. If the system is indeed configured so, go to
Setup Utility
➙
BMC Settings
➙
Network Settings
➙
Network Interface Port
, and select
Shared NIC
.
3. Change network settings as you plan, and save the settings.
4. Go to
Setup Utility
➙
BMC Settings
➙
Network Settings
➙
Network Interface Port
, and select
Dedicated
.
Observable problems
See this section to solve observable problems.
• “The server immediately displays the POST Event Viewer when it is turned on” on page 243
• “Server is unresponsive (POST is complete and operating system is running)” on page 243
• “Server is unresponsive (cannot press F1 to start System Setup)” on page 244
• “Voltage planar fault is displayed in the event log” on page 244
• “Unusual smell” on page 245
• “Server seems to be running hot” on page 245
• “Cannot enter legacy mode after installing a new adapter” on page 245
• “Cracked parts or cracked chassis” on page 245
The server immediately displays the POST Event Viewer when it is turned on
Complete the following procedure to solve the problem.
1. Correct any errors that are indicated by the light path diagnostics LEDs.
2. Make sure that the server supports all the processors and that the processors match in speed and
cache size.
You can view processor details from system setup.
To determine if the processor is supported for the server, see
https://static.lenovo.com/us/en/
3. (Trained technician only) Make sure that processor 1 is seated correctly
4. (Trained technician only) Remove processor 2 and restart the server.
5. Replace the following components one at a time, in the order shown, restarting the server each time:
a. (Trained technician only) Processor
b. (Trained technician only) System board
Server is unresponsive (POST is complete and operating system is running)
Complete the following procedure to solve the problem.
• If you are in the same location as the server, complete the following steps:
243
Summary of Contents for 7D31
Page 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Page 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Page 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Page 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Page 71: ...Chapter 3 Internal cable routing 63 ...
Page 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Page 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Page 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Page 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Page 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Page 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Page 273: ......
Page 274: ......