LAUNCH
X-631 Wheel Aligner Product Service Manual Hardware
2-7
6
7
4
5
Function Description
Switch power supply: input voltage AC220V±10%, output voltage DC9.3±0.1V. When output voltage is
incorrect, adjust the potentiometer with a small cross screwdriver to keep the output voltage within the
specified range.
AC power supply is picked from the power strip of the cabinet via the power supply connecting cable, it
outputs DC power supply to be used by the charging sockets at two sides of cabinet, providing the charging
power supply for probe rods.
Connecting Cable
AC power supply connecting cable
Connection Explanation
1(W)
To L (power cable)
2(B)
To N (power cable)
3(Y-G) GND
(power
cable)
4(B) To
V+(charging
cable)
5(R)
To V- (charging cable)
6
Charging converter cable
at the left side of
cabinet
7
Charging converter cable
at the right side of
cabinet
GND
Live
Null
3
1
2